Clamp on Type Ultrasonic Flow Meter
Clamp on Type Ultrasonic Flow Meter
Manas have now introduced a new Clamp Type Ultrasonic
Flow Meter.
·
Ultrasonic flow
meter works on the Transit Time or Time of Flight
principle.
·
The Flow meter unit utilizes two
transducers that functions as both Ultrasonic transmitter and receiver.
·
The transducers are clamped on to
the outside surface of the closed pipes.
·
The transit time flow meter
measures the time it takes for an ultrasonic signal transmitted from one
transducer to cross the pipe and be received by second transducer.
·
The flow is then measured by
comparing the upstream and downstream time of Ultrasonic signal.
Additional
Information:
Pipe size S: 15-80 mm, M: 50-700 mm, L: 400-4570 mm
Portable case Size: 463x383x103 mm
Accuracy ±1% of reading @ rate >0.5 m/sec.
Velocity ±12 m/sec. Bidirectional
Display 4 lines, 16 characters, LCD with back light, flow rate, velocity & Totalizer.

Comments